RENOLIN ZAF 32D
RENOLIN ZAF 46D
RENOLIN ZAF 68D
无锌和灰分,液压油清洁剂
锌和灰分液压油不断得到普及,在过去的几年里。在许多情况下,使用一个无锌液压油是必须的,特别是在工具机,液压油可以污染其他功能性流体。
液压油是锌和灰分液压油具有良好的洗涤性能。清洁剂在这些油减少形成的残留物和老龄化的副产品。
他们是液压油符合标准6743-4但更多的洗涤剂和分散剂的特点。
最重要的特点renolin南非液压油:
良好的氧化安定性和良好的抗老化
强大的极压性能和很好的抗磨损
良好的腐蚀保护
快速的空气释放性和低泡沫
良好的污泥运输和清洁性能
良好的兼容性与密封材料
应用程序:
renolin南非产品是高档液压油符合标准6743-4可用于所有液压系统也为纵横润滑油符合标准6743-6。renolin南非产品含有添加剂,避免形成的残留物,保证功能机械设备可靠性分析。
OLIN ZAF |
|
32 D |
46 D |
68 D |
|
Hydraulic oil type |
|
|
|
|
|
acc. to ISO 6743-4 |
|
HM 32 |
HM 46 |
HM 68 |
|
acc. to DIN 51 502 |
|
HLPD 32 |
HLPD 46 |
HLPD 68 |
|
Lubricating oil type |
|
|
|
|
|
acc. to ISO 6743-6 |
|
CKC 32 |
CKC 46 |
CKC 68 |
|
acc. to DIN 51 502 |
|
CLP 32 |
CLP 46 |
CLP 68 |
|
Characteristics |
Unit |
|
|
|
Test method |
Colour |
|
1 |
1 |
1 |
ASTM D 1500 |
Kinematic viscosity |
|
|
|
|
|
at 40 °C |
mm²/s |
32 |
46 |
68 |
ASTM D 445 |
at 100 °C |
mm²/s |
5.4 |
6.9 |
8.6 |
ASTM D 445 |
Viscosity index |
|
100 |
105 |
97 |
ASTM D 2270 |
Density at 15 °C |
kg/l |
0.878 |
0.882 |
0.884 |
ASTM D 1298 |
Flash point, Cleveland open cup |
°C |
210 |
230 |
230 |
ASTM D 92 |
Pour point |
°C |
-33 |
-27 |
-24 |
ASTM D 97 |
Neutralization number |
mg KOH/g |
0.35 |
0.35 |
0.35 |
ASTM D 974 |
Saponification number |
mg KOH/g |
1.1 |
1.1 |
1.1 |
ASTM D 94 |
Air release at 50 °C |
min |
3 |
4 |
7 |
ASTM D 3427 |
Foaming, |
|
|
|
|
|
seq. I |
ml |
30/0 |
50/0 |
50/0 |
ASTM D 892 seq. I-III |
seq. II |
ml |
20/0 |
20/0 |
20/0 |
ASTM D 892 seq. I-III |
seq. III |
ml |
20/0 |
20/0 |
20/0 |
ASTM D 892 seq. I-III |
Copper corrosion |
degree of corr. |
1a-100A3 |
1a-100A3 |
1a-100A3 |
ASTM D 130 |
Rust prevention |
|
pass A |
pass A |
pass A |
ASTM D 665 |
Ageing behaviour, increase in neutralization number after 1000 h |
mg KOH/g |
< 2 |
< 2 |
< 2 |
ASTM D 943 |
Brugger boundary friction test |
N/mm² |
38 |
38 |
38 |
DIN 51 347 (D) |
FZG mechanical gear rig test |
load stage |
> 12 |
> 12 |
> 12 |
DIN 51 354-2 |
Vickers vane pump test, loss of mass |
|
|
|
|
|
on ring |
mg |
<120 |
<120 |
<120 |
IP 281 |
on vanes after 250 h |
mg |
<30 |
<30 |
<30 |
IP 281 |
Effect on SRE-NBR 1 seal material acc. to DIN 53 538-1 at 100 °C +/– 1 °C after 7 days +/– 2 hours, |
|
|
|
|
|
relative volume change |
% |
7 |
6 |
5 |
DIN 53 521 together with DIN 53 505 |
change in Shore A hardness |
Shore |
-3 |
-3 |
-2 |
DIN 53 521 together with DIN 53 505 |
|